Plasmid-250-mini Plasmid DNA Extraction Kit

The GeneJET Plasmid Miniprep Kit recovers up to 20 µg of high copy number plasmid DNA per isolation procedure using a silica-based membrane within the spin column. The PureLink HiPure Plasmid Miniprep Kit isolates high yields of pure plasmid DNA from E. coli in less than 2 hours, without the use of organic solvents or […]

Continue reading

Chromogenic Coliforms Agar

List and differentiate coliforms and Escherichia coli in water samples with Thermo Scientific ™ Oxoid ™ Chromogenic Coliform Agar in accordance with ISO 9308-1 guidelines for water quality testing. Target organisms are easy to differentiate, E. coli forms dark blue / purple colonies and pink to red coliforms. Achieve full detection in 24 hours, eliminating […]

Continue reading

GenBody COVID-19 Total Solution

Expected Use The GenBody COVID-19 Ag is a rapid immunochromatographic diagnostic test (RDT) designed for qualitative analysis detection of SARS-CoV-2 nucleocapsid protein antigen in direct nasopharyngeal (NP) or exterior nasal (NA) swab samples from people suspected of COVID-19 by their healthcare provider within the first six days of onset of symptoms, or people without symptoms […]

Continue reading

Universal fc receptor blocker

Non specific Fc receptors staining in assays equal to IHC, ICC, Immunofluorescence (IF) and motion cytometry might find yourself from the binding of the Fc space of the primary and/or secondary antibody or immunoglobulin isotypes to the Fc receptors of the cells. Eliminating Fc receptor staining is fascinating in IHC, ICC, IF and Circulation cytometry […]

Continue reading

Plant Preservative Mixture (PPM)

Plant Preservative Mixture (PPM), is a broad-spectrum biocide/ for plant tissue custom. PPM is the ultimate phrase decision to the countless wrestle in opposition to microbial airborne, waterborne and endogenous contamination. PPM is a heat-stable preservative/biocide which may be utilized to efficiently forestall or reduce microbial contamination in plant tissue customs. At optimum doses, PPM, […]

Continue reading

One Step Diagnostic Rapid Test Cassette

READING TEST RESULTS Optimistic (Pregnant) Two distinct purple strains appear. One line should be throughout the administration space (C) and one different line should be throughout the examine space (T). This means you is likely to be possibly pregnant. Detrimental (Not pregnant) One purple line appears throughout the administration space (C).No apparent purple or pink […]

Continue reading

c-chip disposable hemocytometer slides

Options • Blood cell counting • Cell focus measurement • Cell viability try • Micro organism and fungal spore counting IVF, IUI • Sperm countingFashions • Neubauer Improved (100 µm depth) – DHC-N01 • Fuchs Rosenthal (200 µm depth) – DHC-F01 • Burker (100 µm depth) – DHC-B01 • Burker Turk (100 µm depth) – DHC-B02 • Malassez (200 µm depth) – DHC-M01 EVE […]

Continue reading

NATtrol Meningitis/Encephalitis Panel

ETIOLOGIC STATUS/BIOHAZARD TESTING:  NATtrol inactivation was carried out on the shares used to formulate each administration. The inactivation was verified by the absence of growth in validated tissue custom primarily based infectivity assays and growth protocols.  Purified protein matrix used throughout the manufacture of this product is dealt with with 0.09% sodium azide. […]

Continue reading

DaAn Gene

Description The 2019 Novel Coronavirus (2019-nCoV) RNA Detection Kit (PCR-fluorescence Probing) manufactured by Da An Gene Co., Ltd. of Sun Yat-sen University is available for acquisitions through the Supply Division. The product is offered at a price based on FCA. US $ 400.00 per kit. The price does not include an extraction kit that must […]

Continue reading

Dengue NS1 Antigen

Bottom Early detection of complications significantly reduces mortality and morbidity associated with dengue. We set out to determine whether the rapid NS1 antigen test could be used as a point-of-care test to predict severe disease. Methods 186 adult patients with confirmed dengue were enrolled on days 3-8 of illness. Clinical and laboratory parameters were recorded […]

Continue reading